Communication lines are used to upload and download information between the ACU and the
Veritrax software. Communication between the ACU and PC is displayed by the system’s two
LEDs.
! The RX LED flashes when the controller receives data
! The TX LED flashes when the controller transmits data
! The ACU address is defined in the Veritrax software. For successful communications, the
dipswitch must be defined with the same address.
There are two connection modes:
! Serial
" RS232
" RS485
! LAN
Serial Connection
The PC Serial Port controlling the ACU is assigned in the Network Properties in the Veritrax
software. By default the default is set to 9600 for direct connection to the PC using the
standard RS232 interface.
" RS232 Connection
ACU DB9 Connector DB25 Connector
GND Pin 5 Pin 7
Tx Pin 2 Pin 3
Rx Pin 3 Pin 2
!
The RS232 connection can only be used for one ACU. The distance between the PC and
ACU can be no more than 150 feet (50 meters). If the baud rate is increased to 56000 the
distance can be up to 30 feet (10 meters). J1 must be in the right position to select the RS232
communication.