Technical Specifications
10 AC-B/C/D3x Family Installation and Programming Manual
2. Technical Specifications
Electrical Characteristics
Operating Voltage Range
12–16 VDC
From a regulated power supply
Input Current (excluding
attached devices)
AC-x31 models:
• Standby: 20 mA
• Max: 60 mA
AC-x32 models:
• Standby: 40 mA
• Max: 90 mA
Relay Outputs
• Lock Strike Relay – Electronic, 3.5 A
with built in suppressor protection
• Auxiliary Relay – Form C, 1A (AC-x32
models)
Inputs
• REX – N.O., Dry Contact
• Auxiliary Input (In/Monitor)
• Monitor Mode – N.C., Dry Contact
• Input Mode – N.O., Dry Contact
LEDs
Two tri-colored LEDs
Built-In Proximity Reader
(AC-x32 models)
• Read Range: 90 mm (3.5 in.)*
• Modulation: ASK at 125kHz
• Compatible cards: All 26-Bit EM
cards
Environmental Characteristics
Operating Temperature
-31°C to 63°C (-25°F to 145°F )
Operating Humidity
0 to 95% (non-condensing)