AC-225 Hardware Settings
5.1 DIP Switch Configuration
The access control panel DIP switch controls a number of
operating parameters including the device address and baud
rates for serial communication.
1 2 3 4 5 6 7 8
Figure 14: DIP Switch
The following is a list of DIP switch numbers and their functions:
DIP
Switch
Function
1
2
The panel's communication baud rate.
3 The panel type:
single door controller or double door controller.
4
5
6
7
8
The access control panel's VeriTrax-network
address.
Note:
Power down the access control panel before changing
the DIP switch settings.
After changes have been made, restart the panel. The
new settings are automatically defined after power up.
5.2 Access Control Panel Baud Rate
The Access control panel serial port baud rate, set in dip
switches one and two, defines the communication speed for
connecting with a PC in a network connection.
The default baud rate is set to 9600 bits per second.