AC-225 Hardware Settings
Single Door Controller
This access type has two readers, IN and OUT, as follows:
Outputs Door lock strike
General purpose output
General purpose output
General purpose output
Inputs Release to exit
Door monitor input
General purpose input
General purpose input
Note:
For more information, refer to Input and Output
Requirements on page 16.
Double Door Controller
This access type has two readers, IN and OUT, as follows:
Outputs Door 1 lock strike
General purpose output
Door 2 lock strike
General purpose output
Inputs Release to exit door1
Door 1 monitor input
Release to exit door 2
Door 2 monitor input
5.4 Access Control Panel Addressing
The last 5 DIP switches are used to select the binary coded
access control panel internal network address.
The default access control panel address is “1”.