Rosslare AC-G43 Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Claviers numériques Rosslare AC-G43. Rosslare AC-G43 Instruction manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Instruction Manual

AC-FG4x Family Backlit, Waterproof Stand-Alone controllers Instruction Manual Models: AC-F43 AC-F44 AC-G43 AC-G44 October 2006

Page 2

Installation AC-F4x and AC-G4x Family Manual Page 9 2. Installation 2.1 MOUNTING THE CONTROLLER Prior to starting, select the location where the

Page 3 - Table of Contents

Installation AC-F4x and AC-G4x Family Manual Page 10 6) Once wired, replace the controller back onto its back plate and secure using tamper-proof

Page 4

Installation AC-F4x and AC-G4x Family Manual Page 11 Figure 3: Wiring Diagram for Lock Strike Relay & REX

Page 5 - 1. General Information

Installation AC-F4x and AC-G4x Family Manual Page 12 Figure 4: Wiring Diagram for Auxiliary Input & Output

Page 6 - 1.4 ANCILLARY EQUIPMENT

Installation AC-F4x and AC-G4x Family Manual Page 13 Figure 5: Wiring Diagram for the BL-D40 External Sounder

Page 7 - General Information

Operation AC-F4x and AC-G4x Family Manual Page 14 3. Operation Note: • In the Operation chapter, “code” refers to a PIN code or proximity card

Page 8 - 1.6 KEY FEATURES

Operation AC-F4x and AC-G4x Family Manual Page 15 3.1.3 Bypass Mode • Mode indicator is orange. In bypass mode, access to the premises is depend

Page 9 - 1.7 FRONT PANEL DESCRIPTION

Operation AC-F4x and AC-G4x Family Manual Page 16 3.2.2 Secure User A secure user must have a primary and secondary code assigned, and the two co

Page 10 - 2. Installation

Operation AC-F4x and AC-G4x Family Manual Page 17 3.3.2 From Secure to Normal Mode The default factory setting for the normal / secure code is 383

Page 11 - 2.2 WIRING THE CONTROLLER

Operation AC-F4x and AC-G4x Family Manual Page 18 3.3.4 From Bypass to Normal Mode 1) Enter the normal / bypass code. • Mode indicator will

Page 13

Operation AC-F4x and AC-G4x Family Manual Page 19 Fail Secure Operation: from the moment the REX pushbutton is depressed, the door will be unlocked

Page 14

Operation AC-F4x and AC-G4x Family Manual Page 20 3.4.5 BL-D40 External Sounder The BL-D40 External Sounder is designed for indoor use only and i

Page 15 - 3. Operation

Programming AC-F4x and AC-G4x Family Manual Page 21 4. Programming Note: • In the Programming chapter, “code” refers to a PIN code or proximity

Page 16 - 3.2 USER LEVELS

Programming AC-F4x and AC-G4x Family Manual Page 22 The table below shows all the programming menus, with default factory codes and settings. Def

Page 17 - 3.2.2 Secure User

Programming AC-F4x and AC-G4x Family Manual Page 23 Mode Door Red4.1.1 Entering the Programming Mode Note: • The controller must be in normal mo

Page 18

Programming AC-F4x and AC-G4x Family Manual Page 24 4.2 CHANGING THE OPEN CODE The open code is mainly used as a method to quickly test the Lock

Page 19

Programming AC-F4x and AC-G4x Family Manual Page 25 Note: • Auxiliary code does not function in secure mode. • Auxiliary code only works when th

Page 20 - 3.4.3 Tamper Feature

Programming AC-F4x and AC-G4x Family Manual Page 26 4.5 CHANGING THE NORMAL/SECURE CODE Note: • When the auxiliary mode is 1, 2, 3 or 4, the au

Page 21

Programming AC-F4x and AC-G4x Family Manual Page 27 3) Hereafter, are four different ways to program the normal / bypass code and door chime. a.

Page 22 - 4. Programming

Programming AC-F4x and AC-G4x Family Manual Page 28 3) Construct a code using instructions hereafter. First Digit For fail secure operation, the

Page 23 - Programming

Table of Contents AC-F4x and AC-G4x Family Manual Page ii Table of Contents 1. General Information...

Page 24

Programming AC-F4x and AC-G4x Family Manual Page 29 3) Construct a code using the instructions hereafter. The Quick Reference Guide for Auxiliar

Page 25 - 4.2 CHANGING THE OPEN CODE

Programming AC-F4x and AC-G4x Family Manual Page 30 4.8.2 Quick Reference Guide for Auxiliary Mode Setting Auxiliary Mode Auxiliary Input Functio

Page 26

Programming AC-F4x and AC-G4x Family Manual Page 31 4.8.3 Detailed Reference Guide The following are brief descriptions of each auxiliary mode. To

Page 27

Programming AC-F4x and AC-G4x Family Manual Page 32 AUXILIARY MODE 2 Auxiliary input function: Toggles normal/secure modes Auxiliary output acti

Page 28

Programming AC-F4x and AC-G4x Family Manual Page 33 AUXILIARY MODE 4 Auxiliary input function: Toggles normal/secure modes Auxiliary output activ

Page 29 - 4.8 SETTING AUXILIARY MODES

Programming AC-F4x and AC-G4x Family Manual Page 34 AUXILIARY MODE 6 Auxiliary input function: Door Monitor Auxiliary output activated by: Forced

Page 30

Programming AC-F4x and AC-G4x Family Manual Page 35 AUXILIARY MODE 8 Auxiliary input function: Green LED control Auxiliary output activated by: V

Page 31

Programming AC-F4x and AC-G4x Family Manual Page 36 4.9 SETTING THE LOCKOUT FEATURE In case the controller is presented with wrong codes, (PIN or

Page 32

Programming AC-F4x and AC-G4x Family Manual Page 37 4.10 BACKLIGHT and LED BEHAVIOR The controller allows you to define the way the units' Ba

Page 33

Programming AC-F4x and AC-G4x Family Manual Page 38 • Primary codes cannot be the same as system codes, such as the normal / secure code or the o

Page 34

Table of Contents AC-F4x and AC-G4x Family Manual Page iii 4. Programming...

Page 35

Programming AC-F4x and AC-G4x Family Manual Page 39 4.11.4 Standard Method for Codes Enrolling 1) Enter the programming mode. 2) Depress 7 to e

Page 36

Programming AC-F4x and AC-G4x Family Manual Page 40 4.11.5 Search Method for Codes Enrolling The code search method enables to quickly enroll a s

Page 37

Programming AC-F4x and AC-G4x Family Manual Page 41 Note: It is recommended that a record be kept of added and deleted users. This makes it easier

Page 38 - 4.11 ENROLLING CODES

Programming AC-F4x and AC-G4x Family Manual Page 42 • The Door indicator will flash orange. The controller is now waiting for the primary code o

Page 39

Programming AC-F4x and AC-G4x Family Manual Page 43 4.13 RELAY CODES ASSIGNMENT When a primary code is enrolled for any user, the user is authoriz

Page 40

Programming AC-F4x and AC-G4x Family Manual Page 44 4.13.2 Relay Code Assignment using Search Method 1) Enter the programming mode. 2) Depress

Page 41 - 4.12 DELETING CODES

Programming AC-F4x and AC-G4x Family Manual Page 45 4.14 PIN CODE LENGTH / FACTORY DEFAULT SETTINGS Warning: You must be very careful before usin

Page 42

Programming AC-F4x and AC-G4x Family Manual Page 46 4.15 REPLACING A PROGRAMMING CODE Note: The controller must be in its normal mode for the pr

Page 43

Limited Warranty AC-F4x and AC-G4x Family Manual Page 47 Appendix A. Limited Warranty ROSSLARE ENTERPRISES LIMITED S (Rosslare) FIVE YEARS LIMITED

Page 44 - 4.13 RELAY CODES ASSIGNMENT

Limited Warranty AC-F4x and AC-G4x Family Manual Page 48 Exclusions and Limitations ROSSLARE shall not be responsible or liable for any damage o

Page 45

General Information AC-F4x and AC-G4x Family Manual Page 4 1. General Information 1.1 INTRODUCTION The AC-F4x series and AC-G4x series Access Co

Page 46 - SETTINGS

Technical Support AC-F4x and AC-G4x Family Manual Page 49 Appendix B. Technical Support Asia Pacific, Middle East, Africa Rosslare Security Product

Page 48 - Appendix A. Limited Warranty

0706-0960101+01 www.rosslaresecurity.com

Page 49 - Limited Warranty

General Information AC-F4x and AC-G4x Family Manual Page 5 1.3 BOX CONTENT Before beginning verify that all of the following is in the box, if any

Page 50 - Technical Support

General Information AC-F4x and AC-G4x Family Manual Page 6 1.5 TECHNICAL SPECIFICATIONS AC-F43 AC-F44 AC-G43 AC-G44 VDC 12-24 V DC Input Voltage

Page 51

General Information AC-F4x and AC-G4x Family Manual Page 7 1.6 KEY FEATURES • 500 Users • Water resistant • Programmable Backlight and active L

Page 52 - 0706-0960101+01

General Information AC-F4x and AC-G4x Family Manual Page 8 1.7 FRONT PANEL DESCRIPTION Figure 1: Front Panel

Commentaires sur ces manuels