Programming
3) Construct a code using instructions hereafter.
? ? ? ?
First Digit
For fail secure operation, the first digit is set to 0.
For failsafe operation, the first digit is set to 1.
Second Digit
Siren time, enter any number from
0 to 9 (minutes).
Third and Fourth Digits
The Lock Strike is to be released after the
number of seconds entered (1 to 99).
For example 0 5 1 2 means: fail secure operation (0), with5 minutes
siren time (5) and a 12-second Lock Strike release time (12).
4) System returns to its normal mode.
Mode
Door
Green
You will hear three beeps.
The Door indicator will turn off.
The Mode indicator will turn green.
4.8 SETTING AUXILIARY MODES
4.8.1 General
The default auxiliary setting is 2004.
Mode
Door
Green
1) Enter the Programming Mode.
2) Depress 6 to enter Menu 6.
Mode Door
Green
Green
The Mode indicator will flash green
Page 33 AC-Q4x Family, Installation and user Manual